All articles

How to install the Magnetic Door SensorUpdated 3 months ago

This is a smart door sensor that adopts low power consumption Zigbee wireless network technology. This enables longer battery life. It can detect the open or closed state of the door or window through the closure and separation between the sensor and magnetic. The dual sensor design makes the installation more flexible and adaptable. The products are suitable for homes, villas, factories, stores, stores, warehouses, office buildings, banks, rooms and other security prevention places.

Installation Instructions

Step 1:

Remove the insulating film from the battery to turn on the sensor.

Step 2:

Enter the network: As directed by the application, press the network button for 2 seconds until the green LED flashes rapidly, then the green LED stays on for 3 seconds, indicating successful network entry.

Exit the network: Press the network button for 5 seconds to exit the network. If the green LED flashes slowly for 3 seconds, it indicates that the device has successfully exited the network.

Device LED indicator instruction.

Add network:

When pressing the network button for 2 seconds, the green LED flashes (twice per second).

Exit network:

Green LED flashes six times (once per second).

Alarm:

The red LED flashes once.   

Step 3 Align the installation, the installation distance is less than 15mm.

Align the installation, the installation distance is less than 15 mm. (The magnet part can be installed on both sides of the sensor part.

Step 4 

Remove the sticky film and stick the equipment in the required area. The sensor should be installed in a fixed area such as the door frame, the magnet can be installed in an active area such as the door plank; this image is for reference only.

Note: preferably, always fix the magnetic contact and magnet with dowel and dowel pin.

Step 5

Install the sensors on the bracket:

Battery Replacement 

-Replace the battery according to the negative and positive of the battery. 

-Treat used batteries correctly to protect the environment.

Technical parameters:

Working voltage: DC3V (2 AAA batteries).

Sensing distance: >15mm

Network: Zigbee

Wireless network distance: Approx. 70m (Open area without obstacles)

Working Temperature: 0°C~+40°C

Working Humidity: 10% to 80% RH (Non-condensing)

Sensor dimensions: 76 × 36.6 × 16.5mm

Magnet dimensions: 76 × 13.9 × 16.5mm

Functional diagram:

Do you have any questions or queries? Contact us by WhatsApp at +52 56 2542 9432! We will be happy to help you. 

Was this article helpful?
Yes